An Evaluation of Using Real-time Volumetric Display of 3D Ultrasound Data for Intracardiac Catheter Manipulation Tasks

dc.contributor.authorWang, Aaron S.en_US
dc.contributor.authorNarayan, Girishen_US
dc.contributor.authorKao, Daviden_US
dc.contributor.authorLiang, Daviden_US
dc.contributor.editorKlaus Mueller and Thomas Ertl and Eduard Groelleren_US
dc.date.accessioned2014-01-29T17:43:08Z
dc.date.available2014-01-29T17:43:08Z
dc.date.issued2005en_US
dc.description.abstractThe enthusiasm for novel, minimally invasive, catheter based intracardiac procedures has highlighted the need to provide accurate, real-time, anatomically based image guidance to decrease complications, improve precision, and decrease fluoroscopy time. The recent development of real-time 3D echocardiography creates the opportunity to greatly improve our ability to guide minimally invasive procedures [Ahm03]. However, the need to present 3D data on a 2D display decreases the utility of 3D echocardiography because echocardiographers cannot readily appreciate 3D perspective on a 2D display without ongoing image manipulation. We evaluated the use of a novel strategy of presenting the data in a true 3D volumetric display, Perspecta Spatial 3D System (Actuality Systems, Inc., Burlington, MA). Two experienced echocardiographers performed the task of identifying the targeted location of a catheter within 6 different phantoms using four display methods. Echocardiographic images were obtained with a SONOS 7500 (Philips Medical Systems, Inc., Andover, MA). Completion of the task was significantly faster with the Perspecta display with no loss in accuracy. Echocardiography in 3D significantly improves the ability of echocardiography for guidance of catheter based procedures [Ahm03]. Further improvement is achieved by using a true 3D volumetric display, which allows for more intuitive assessment of the spatial relationships of catheters in three-dimensional space compared with conventional 2D visualization modalities.en_US
dc.description.seriesinformationVolume Graphics 2005en_US
dc.identifier.isbn3-905673-26-6en_US
dc.identifier.issn1727-8376en_US
dc.identifier.urihttps://doi.org/10.2312/VG/VG05/041-045en_US
dc.publisherThe Eurographics Associationen_US
dc.subjectKeywords: 3D echocardiography, cardiac ablation, computer graphics, display technologies, intracardiac catheter procedures, Perspecta display, medical visualization, volume graphics, volumetric display.en_US
dc.titleAn Evaluation of Using Real-time Volumetric Display of 3D Ultrasound Data for Intracardiac Catheter Manipulation Tasksen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
041-045.pdf
Size:
6.79 MB
Format:
Adobe Portable Document Format