• Login
    View Item 
    •   Eurographics DL Home
    • Eurographics Workshops and Symposia
    • VCBM: Eurographics Workshop on Visual Computing for Biomedicine
    • VCBM 16: Eurographics Workshop on Visual Computing for Biology and Medicine
    • View Item
    •   Eurographics DL Home
    • Eurographics Workshops and Symposia
    • VCBM: Eurographics Workshop on Visual Computing for Biomedicine
    • VCBM 16: Eurographics Workshop on Visual Computing for Biology and Medicine
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Temporal Interpolation of 4D PC-MRI Blood-flow Measurements Using Bidirectional Physics-based Fluid Simulation

    Thumbnail
    View/Open
    059-068.pdf (6.372Mb)
    additional_materials.pdf (112.3Kb)
    videofinal.mp4 (7.143Mb)
    Date
    2016
    Author
    Hoon, Niels H. L. C. de
    Jalba, Andrei C.
    Eisemann, Elmar ORCID
    Vilanova, Anna
    Pay-Per-View via TIB Hannover:

    Try if this item/paper is available.

    Metadata
    Show full item record
    Abstract
    Magnetic Resonance Imaging (MRI) enables volumetric and time-varying measurements of blood-flow data. Such data have shown potential to improve diagnosis and risk assessment of various cardiovascular diseases. Hereby, a unique way of analysing patient-specific haemodynamics becomes possible. However, these measurements are susceptible to artifacts, noise and a coarse spatio-temporal resolution. Furthermore, typical flow visualization techniques rely on interpolation. For example, using pathlines requires a high quality temporal resolution. While numerical simulations, based on mathematical flow models, address some of these limitations, the involved modelling assumptions (e.g., regarding the inflow and mesh) do not provide patientspecific data to the degree actual measurements would. To overcome this issue, data assimilation techniques can be applied to use measured data in order to steer a physically-based simulation of the flow, combining the benefits of measured data and simulation. Our work builds upon such an existing solution to increase the temporal resolution of the measured data, but achieves significantly higher fidelity. We avoid the previous damping and interpolation bias towards one of the measurements, by simulating bidrectionally (forwards and backwards through time) and using sources and sinks. Our method is evaluated and compared to the, currently-used, conventional interpolation scheme and forward-only simulation using measured and analytical flow data. It reduces artifacts, noise, and interpolation error, while being closer to laminar flow, as is expected for flow in vessels.
    BibTeX
    @inproceedings {10.2312:vcbm.20161272,
    booktitle = {Eurographics Workshop on Visual Computing for Biology and Medicine},
    editor = {Stefan Bruckner and Bernhard Preim and Anna Vilanova and Helwig Hauser and Anja Hennemuth and Arvid Lundervold},
    title = {{Temporal Interpolation of 4D PC-MRI Blood-flow Measurements Using Bidirectional Physics-based Fluid Simulation}},
    author = {Hoon, Niels H. L. C. de and Jalba, Andrei C. and Eisemann, Elmar and Vilanova, Anna},
    year = {2016},
    publisher = {The Eurographics Association},
    ISSN = {2070-5786},
    ISBN = {978-3-03868-010-9},
    DOI = {10.2312/vcbm.20161272}
    }
    URI
    http://dx.doi.org/10.2312/vcbm.20161272
    https://diglib.eg.org:443/handle/10.2312/vcbm20161272
    Collections
    • VCBM 16: Eurographics Workshop on Visual Computing for Biology and Medicine

    Eurographics Association copyright © 2013 - 2023 
    Send Feedback | Contact - Imprint | Data Privacy Policy | Disable Google Analytics
    Theme by @mire NV
    System hosted at  Graz University of Technology.
    TUGFhA
     

     

    Browse

    All of Eurographics DLCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    BibTeX | TOC

    Create BibTeX Create Table of Contents

    Eurographics Association copyright © 2013 - 2023 
    Send Feedback | Contact - Imprint | Data Privacy Policy | Disable Google Analytics
    Theme by @mire NV
    System hosted at  Graz University of Technology.
    TUGFhA