A Mathematical Model and Calibration Procedure for Galvanometric Laser Scanning Systems

Loading...
Thumbnail Image
Date
2011
Journal Title
Journal ISSN
Volume Title
Publisher
The Eurographics Association
Abstract
Laser galvanometric scanning systems are commonly used in various fields such as three dimensional scanning, medical imaging, material processing, measurement devices and laser display systems. The systems of such kind suffer from distortions. On top of that they do not have a center of projection, which makes it impossible to use common projector calibration procedures. The paper presents a novel mathematical model to predict the image distortions caused by galvanometric mirror scanning systems. In addition, we describe a calibration procedure for recovering its intrinsic and extrinsic parameters.
Description

        
@inproceedings{
10.2312:PE/VMV/VMV11/207-214
, booktitle = {
Vision, Modeling, and Visualization (2011)
}, editor = {
Peter Eisert and Joachim Hornegger and Konrad Polthier
}, title = {{
A Mathematical Model and Calibration Procedure for Galvanometric Laser Scanning Systems
}}, author = {
Manakov, Alkhazur
 and
Seidel, Hans-Peter
 and
Ihrke, Ivo
}, year = {
2011
}, publisher = {
The Eurographics Association
}, ISBN = {
978-3-905673-85-2
}, DOI = {
10.2312/PE/VMV/VMV11/207-214
} }
Citation
Collections